Abstract

During retrieval and disposition of wastes containing transuranium elements, continuous monitoring of the air, water, and soil for alpha emitters was required to ensure that safety limits were not exceeded and that the waste itself was not disturbed unknowingly. Direct measurements by alpha spectrometry were particularly promising because of their potential speed, sensitivity, and their ability to identify transuranium radionuclides under field conditions. Soil samples or settled dusts were finely ground, suspended in 80% ethanol, sprayed onto circular stainless steel pans, and dried on a hotplate. Water samples were mounted directly by spraying. Air dusts were collected with a high-volume air sampler on 20- by 25-cm membrane filters. The samples were then analyzed directly in a large pressurized gridded ionization chamber without further sample preparation. The lower limits of detection for 10-min counting times were 1.5 Bq g-1 (40 pCi g-1) for 100-mg soil samples, and 4 x 10(-2) Bq m-3 (10(-12) microCi mL-1) for a 10-min air sample taken at 0.4 m3 min-1 (14 cubic feet per minute) and counted without waiting for decay of radon progeny.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.