Abstract

Rapid mixing has been achieved in a pressure-driven microflow which is forced under AC electric field. In our previous investigations, the mixing on large scale at the centerline of microchannel has been studied. Here, we show that the evaluation on mixing effect by flow visualization could be misleading, if its temporal resolution is not sufficiently high. By using single-point laser induced fluorescence (LIF) method, the mixing on both large and small scales can be investigated with high spatiotemporal resolution. It is found fast mixing is not only achieved at the centerline, but also in the majority of cross-sectional area, even near the bottom wall region. This is resulted from the large scale secondary flow due to unbalanced AC electroosmotic flow near the bottom wall. The temporal −5/3 spectrum of concentration measured with LIF in our previous investigations is also supported by the spatial spectrum of concentration. The physical process of mixing on small scales is further investigated by the flatness of concentration gradients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.