Abstract

This study investigates the mixing phenomena between ferro-nanofluid (a water solution with suspended Fe 3O 4 nanoparticles) and water in a Y-type semi-active micromixer. A permanent magnet with a magnetic strength of 2200 G was installed directly under the mixer at a location behind the junction of the Y-type micromixer to improve the mixing between ferro-nanofluid and water. The permanent magnet is 9.6 mm long, 9.6 mm wide and 1.6 mm thick. Equal volumetric flow rates for both ferro-nanofluid and water were tested in two different channel widths, 300 μm and 500 μm. Three different volumetric flow rates of 3 μL/min, 6 μL/min, and 10 μL/min were analyzed to determine the effect of flow rate on the mixing of fluids in the micromixer. Since Fe 3O 4 nanoparticles in the ferro-nanofluid are strongly affected by a relatively uniform magnetic field from the permanent magnet, measured results show that a rapid mixing between ferro-nanofluid and water can be achieved immediately downstream of the permanent magnet for all volumetric flow rates and all channel widths tested in this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.