Abstract

A thin-layer chromatographic (TLC) screening method was developed for the detection of ochratoxin A (OTA) in green coffee at a control level of 10 microg/kg. The method is based on extraction of OTA with a mixture of phosphoric acid and dichloromethane, purification by liquid-liquid partition into sodium hydrogen carbonate, separation by normal-phase TLC, and detection by visual estimation of fluorescence intensity under a UV lamp at 366 nm. The method was validated by performing replicate analyses of uncontaminated green coffee material spiked at 3 different levels of OTA (5, 10, and 20 microg/kg), and also by comparing results obtained on a series of test trial green coffees naturally contaminated with OTA (range 0.2 to 136.7 microg/kg) with those measured by a quantitative immunoaffinity/HPLC method. The agreement between the two methods was excellent, and neither false positive nor false negative results were recorded. This screening method is rapid, simple, robust, and very cheap, which makes it particularly well adapted for implementation in coffee-producing countries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.