Abstract

Several mutations have been identified in the gene coding for Complement Factor H (FH) from patients with atypical Hemolytic Uraemic Syndrome (aHUS), Age-related Macular Degeneration (AMD) and Membranoproliferative Glomerulonephritis (MPGN). These data allow for a precise description of the structural changes affecting FH, but a simple test for specifically assessing FH function routinely is not yet of common use. We have produced and characterised a monoclonal antibody (5H5) which discriminates between FH and the smaller FH-like 1 and FH-related proteins and show here that it specifically binds to FH without detecting the smaller isoforms. We therefore used this mAb for a quick, one-step micro-purification of FH directly from control sera and showed that this affinity chromatography procedure is not disruptive of its cofactor function. We also developed a modified sheep erythrocytes haemolysis test using our antibody and affinity-purified FH. These tests can be used in conjunction for assessing the function of FH purified from patients affected by FH-related diseases. Moreover we used this mAb to develop a FH-specific ELISA test.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call