Abstract

A rapid GLC procedure for the precise estimation of salicylic acid in codeine- and propoxyphene-type capsule and tablet analgesic formulations is presented. The sample material is treated with diazomethane prepared in tetrahydrofuran solution, and the salicylic acid is eluted as its methyl ester. Methyl o-methoxybenzoate serves as the internal standard. Peak areas are quantitated by means of an electronic digital integrator of wide input signal range capacity. The results obtained by applying the method to the analysis of 25 commercial preparations were in excellent agreement with those given by the trap column spectrophotometric procedure, except at salicylic acid levels exceeding about 15%. The proposed GLC technique precludes some drawbacks of the column method and is superior in many respects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.