Abstract

BackgroundGenomic profiling of tumors from cancer patients facilitates molecular-guided therapy. The turnaround time is one of important issues to deliver results timely for clinical decisions. The Ion Torrent™ Genexus™ Integrated Sequencer automates all next generation sequencing (NGS) workflows and delivers results within a day.MethodsIn this study, we conducted a feasibility study to evaluate the detection rate of genomic alterations from cell-free total nucleic acid (cfTNA, containing cfDNA and cfRNA) of 119 non-small cell lung cancer using Oncomine Precision Assay on Genexus™ Integrated Sequencer. Oncomine Precision Assay (OPA) covers actionable mutations, copy number variations and fusion genes and that are applicable for the selection of targeted therapy. cfTNA isolated from plasma (derived from 14 ml of blood) were subjected to the Genexus system for library construction, templating, sequencing, and data analyses.ResultsThe sequencing resulted in median overall depth of 35,773× and median molecular coverage of 2,192× with cfTNA input ranged from 11 to 36 ng. Among the 119 samples evaluated, we detected at least one genomic alteration in plasma cfTNA of 79 cases (66%). When comparing to standard-of-care testing, the sensitivity and specificity of mutation detection in non-small cell lung cancer related genes using liquid biopsy with Genexus-OPA ranged between 49–67% and 93–100%, respectively. 59% of actionable mutations, which were present in tumor tissues, were detected by the Genexus- Oncomine Precision Assay using plasma cfTNA. Among the 5 mutations detected from liquid biopsy only, three mutations are of level 1 evidence according to OncoKB database, highlighting the clinical utilities of liquid biopsy in addressing tumor heterogeneity. Extrathoracic metastasis and levels of lactate dehydrogenase (LDH), C-reactive protein (CRP) and Carcinoembryonic Antigen (CEA) are found to be associated with increased circulating tumor DNA detection.ConclusionsThe Genexus™ Integrated Sequencer system is an automated, accurate NGS system with short turnaround time (TAT) that could assist clinicians to make more timely decision.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.