Abstract

A simple and quick method for the determination of dimethoate, parathion-methyl, fenthion, parathion-ethyl, and methidathion in olive oil is described. Analysis was carried out using GC (capillary column 5 m × 0.32 mm × 0.45 μm) with aspecific detector (FPD), after sample extraction with acetonitrile. No cleanup was necessary because there were no interferences in the chromatogram. Recoveries of five pesticides at three fortification levels (1.0, 0.2 and 0.05 mg/kg) were in the range 78–97%. Seventy-nine samples were collected from Sicilian and Apulian individual growers during 2002–2003. Only 16% of the samples contained fenthion in concentrations ranging from 0.09 to 0.73 mg/kg; no other pesticides were detected in the 79 samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.