Abstract

Image‐guided surgery is currently performed using frame‐based as well as frameless approaches. In order to reduce the invasive nature of stereotactic guidance and the cost in both equipment and time required within the operating room, we investigated the use of rapid prototyping (RP) technology. In our approach, we fabricated custom patient‐specific face masks and guides that can be applied to the patient during stereotactic surgery. While the use of RP machines has previously been shown to be satisfactory from an accuracy standpoint, one of our design criteria – completing the entire build and introduction into the sterile field in less than two hours – was unobtainable. (1) Our primary problems were the fabrication time and the nonresistance of the built material to high‐temperature sterilization. In the current study, we have investigated the use of subtractive rapid prototyping (SRP) machines to perform the same quality of surgical guidance, while improving the fabrication time and allowing for choosing materials suitable for sterilization. Because SRP technology does not offer the same flexibility as RP in terms of prototype shape and complexity, our software program was adapted to provide new guide designs suitable for SRP fabrication. The biopsy guide was subdivided for a more efficient build with the parts being uniquely assembled to form the final guide. The accuracy of the assembly was then assessed using a modified Brown‐Roberts‐Wells phantom base by which the position of a biopsy needle introduced into the guide can be measured and compared with the actual planned target. These tests showed that: 1) SRP machines provide an average technical accuracy of 0.77 mm with a standard deviation of the mean of 0.07 mm, and 2) SRP allows for fabrication and sterilization within three‐and‐a‐half hours after diagnostic image acquisition. We are confident that technology is capable of reducing this time to less than one hour. Further tests are being conducted to determine the registration accuracy of the face mask on the patient's head under IRB‐approved trials. The accuracy of this new guidance technology will be verified by judging it against current frame‐based or frameless systems.PACS number: 87.57.Gg

Highlights

  • 261 Rajon et al.: Custom biopsy guides of diagnostic images, 2) evaluate alternate surgical approaches through the manipulation of the patient-specific 3D model, and 3) apply a virtual surgical plan to the real world patient at the time of surgery

  • The frame-based procedure involves the application of a stereotactic frame to the patient prior to image data acquisition.[3,4] The frame remains on the patient through the entire procedure and serves to attach various apparatuses that are needed during both image acquisition and surgical procedure.[5,6] Frame-based procedures continue to provide the highest degree of accuracy and precision for IGS, but they require the patient to wear the rigid frame during the entire stereotactic procedure

  • The series of tests proposed in this study demonstrated that programmable milling machines are suitable for building image-guided biopsy guides

Read more

Summary

Introduction

261 Rajon et al.: Custom biopsy guides of diagnostic images, 2) evaluate alternate surgical approaches through the manipulation of the patient-specific 3D model, and 3) apply a virtual surgical plan to the real world patient at the time of surgery. This process is termed image-guided surgery (IGS).(2) These three fundamental steps have improved significantly over the last decades due to the increase of computational power and to a continuous improvement of engineering and technology. The first, and older, technology involves the use of a rigid frame This technology remains popular with ­primary applications involving intracranial radiosurgery and biopsy. The frame-based procedure involves the application of a stereotactic frame to the patient prior to image data acquisition.[3,4] The frame remains on the patient through the entire procedure and serves to attach various apparatuses that are needed during both image acquisition and surgical procedure.[5,6] Frame-based procedures continue to provide the highest degree of accuracy and precision for IGS, but they require the patient to wear the rigid frame during the entire stereotactic procedure

Methods
Results
Conclusion
Full Text