Abstract

In this paper, an atmospheric touchable surface dielectric barrier discharge nonthermal plasma system was introduced. The typical plasma area, pulsed voltage, pulsed current, pulse frequency, and plasma power are 459 cm2, 6 kV, 5.5 A, 10 kHz and 140 W, respectively. Its disinfection performance was evaluated on agar plate, glass, and silicone hand by four bacteria including Escherichia coli, Staphylococcus aureus, Staphylococcus albus , and Pseudomonas aeruginosa . The efficiency of plasma disinfection was enhanced with increasing voltage and frequency, but had no significant difference with bacteria type. For a 10-s treatment of agar and silicone hand, the log reductions of bacteria were 2.35–2.6 and 2.85–3.26, respectively. After a 5-s treatment of glass, 3.3–3.68 log reduction of bacteria could be obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.