Abstract

The rapid diagnosis of tuberculosis recurrence can be challenging due to persistently positive detection of Mycobacterium tuberculosis-specific DNA from sputum and bronchopulmonary samples in the absence of active disease. We compared the diagnostic accuracy of the detection of M. tuberculosis-specific DNA by either Xpert (January 2010-June 2018) or Xpert Ultra (July 2018-June 2020) and M. tuberculosis-specific ELISPOT in bronchoalveolar lavage (BAL) samples with M. tuberculosis culture results from sputum or bronchopulmonary samples in patients with suspected recurrence of pulmonary tuberculosis. Among 44 individuals with previous tuberculosis and a presumptive diagnosis of recurrent pulmonary tuberculosis, 4/44 (9.1%) were diagnosed with recurrent tuberculosis by culture. DNA of M. tuberculosis was detected by Xpert in BAL fluid in 1/4 (25%) individuals with recurrent tuberculosis and in 2/40 (5%) cases with past tuberculosis without recurrence, while BAL-ELISPOT with a cut-off of >4,000 early secretory antigenic target-6-specific or culture filtrate protein-10-specific interferon-γ-producing lymphocytes per 1 million BAL-lymphocytes was positive in 4/4 (100%) individuals with recurrent tuberculosis and in 2/40 (5%) cases of past tuberculosis without recurrence. M. tuberculosis-specific BAL-ELISPOT is more accurate than BAL-Xpert for the diagnosis of paucibacillary tuberculosis recurrence.