Abstract

A portable fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded ground beef samples. The principle of the system is a sandwich immunoassay using cyanine 5 dye-labeled polyclonal anti-E. coli O157:H7 antibodies for generation of a specific fluorescent signal. Signal acquisition is effected by launching light from a 635-nm diode laser into a dual tapered 600-μm silica fiber. Fluorescent molecules within approximately 100nm of the fiber surface are excited by the evanescent field, and a portion of the emission recouples into the fiber. A photodiode allows for quantitation of the collected emission light at wavelengths of 670 to 710 nm. Biotin–avidin interactions are used to attach polyclonal antibodies specific for E. coli O157:H7 to the final 7.5 cm of the fiber probe. The biosensor was able to detect E. coli O157:H7 to 3 to 30 CFU/ml in seeded ground beef samples. The reaction was highly specific. Signals with Listeria monocytogenes, Salmonella Typhimurium, or E. coli nonO157:H7 were 2 to 3% of those observed with a similar concentration of E. coli O157:H7. Assays were conducted at or near real-time with results obtained within 20 min of sampling.