Abstract

Amoebic liver abscess (ALA) is a significant public health concern in tropical countries. Traditional diagnostic methods, such as microscopy, have low sensitivity, and nested polymerase chain reaction (nPCR) has lengthy turnaround times. In this study, we aimed to evaluate the effectiveness of the recombinase polymerase amplification (RPA) assay for detecting Entamoeba histolytica in amoebic liver pus samples. The assay was tested on 150 clinical pus samples collected from suspected ALA patients in the emergency department of a tertiary care center located in Chandigarh, northern India. For comparison with RPA, nPCR was also performed on these samples. Of 150 samples, 79 (53%) tested positive for E. histolytica using the RPA assay, and similar (79; 53%) number of samples tested positive with nested PCR. In addition, sequences obtained through Sanger sequencing showed high similarity with other sequences in the National Center for Biotechnology Information database and were submitted to the database. Our findings highlight the potential of RPA as a valuable tool for the accurate diagnosis of ALA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.