Abstract
The application of attenuated total reflectance mid-infrared microspectroscopy (MIR-microspectroscopy) was evaluated as a rapid method for detection and quantification of milk adulteration. Milk samples were purchased from local grocery stores (Columbus, OH, USA) and spiked at different concentrations of whey, hydrogen peroxide, synthetic urine, urea and synthetic milk. Samples were place on a 192-well microarray slide, air-dried and spectra were collected by using MIR-microspectroscopy. Pattern recognition analysis by Soft Independent Modeling of Class Analogy (SIMCA) showed tight and well-separated clusters allowing discrimination of control samples from adulterated milk. Partial Least Squares Regression (PLSR) showed standard error of prediction (SEP) ∼2.33, 0.06, 0.41, 0.30 and 0.014g/L for estimation of levels of adulteration with whey, synthetic milk, synthetic urine, urea and hydrogen peroxide, respectively. Results showed that MIR-microspectroscopy can provide an alternative methodology to the dairy industry for screening potential fraudulent practice for economic adulteration of cow’s milk.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.