Abstract

BackgroundSurgical aortic valve replacement using conventional biological valves (CBVs) is the standard of care for treatment of old patients with aortic valve disease. Recently, rapid deployment valves (RDVs) have been introduced. ObjectivesThe purpose of this study was to report the nationwide German experience concerning RDVs for treatment of aortic valve stenosis and provide a head-to-head comparison with CBVs. MethodsA total of 22,062 patients who underwent isolated surgical aortic valve replacement using CBV or RDV between 2011 and 2015 were enrolled into the German Aortic Valve Registry. Baseline, procedural, and in-hospital outcome parameters were analyzed for CBVs and RDVs using 1:1 propensity score matching. Furthermore, 3 RDVs were compared with each other. ResultsA total of 20,937 patients received a CBV, whereas 1,125 patients were treated with an RDV. Patients treated with an RDV presented with significantly reduced procedure (160 min [25th to 75th percentile: 135 to 195 min] vs. 150 min [25th to 75th percentile: 127 to 179 min]; p < 0.001), cardiopulmonary bypass (83 min [25th to 75th percentile: 68 to 104 min] vs. 70 min [25th to 75th percentile: 56 to 87 min]; p < 0.001), and aortic cross clamp times (60 min [25th to 75th percentile: 48 to 75 min] vs. 44 min [25th to 75th percentile: 35 to 57 min]; p < 0.001), but showed significantly elevated rates of pacemaker implantation (3.7% vs. 8.8%; p < 0.001) and disabling stroke (0.9% vs. 2.2%; p < 0.001), whereas in-hospital mortality was similar (1.7% vs. 2.2%; p = 0.22). These findings persisted after 1:1 propensity score matching. Comparison of the 3 RDVs revealed statistically nonsignificant different pacemaker rates and significantly different post-operative transvalvular gradients. ConclusionsIn this large, all-comers database, the incidence of pacemaker implantation and disabling stroke was higher with RDVs, whereas no beneficial effect on in-hospital mortality was seen. The 3 RDVs presented different complication profiles with regard to pacemaker implantation and transvalvular gradients. (German Aortic Valve Registry [GARY]; NCT01165827)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.