Abstract
Abstract For long-lasting, reinforced-concrete structures exposed to the environment, low permeability concretes are required. ASTM C 1202 (Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration) is a rapid test that indirectly measures the permeability of concrete. The results of the rapid test have been related to direct measurements of permeability (e.g., ponding test) and have been found to be useful and valid provided that possible interferences are accounted for. For comparisons between tests, similar concretes should be tested at similar ages. The addition of silica fume results in a reduction in the permeability of concretes. The rapid test has been able to provide information on relative permeability of concretes with or without silica fume. This finding has been confirmed by the results of the extended ponding test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.