Abstract

Mefenamic acid (MA) is a nonsteroidal antiinflammatory analgesic agent widely used clinically. A simple and sensitive liquid-chromatographic assay has been developed for the quantitative determination of MA in human plasma. A reverse phase, 10-microns cyano column (25 x 0.4 cm), a mobile phase of water-acetonitrile-methanol-17 M acetic acid (69:15:15:1 by volume), and an ultraviolet detection (290 nm) are used for the separation of MA and internal standard (methyl-clonazepam). MA and internal standard are extracted from acidified plasma into diethyl ether and after evaporation of the organic phase, the residue is redissolved in methanol. Calibration curves are linear in the range 0.05-3.20 micrograms/ml, and at the plasma level corresponding to the quantification limit (0.05 microgram/ml) coefficients of variation are 7.5% and 10.2% for repeatability and reproducibility studies, respectively. This assay was successfully used in the study of pharmacokinetics of MA in human plasma after a single oral administration of a low MA dose.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call