Abstract

A rapid and sensitive analytical method for udenafil in rat plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). This chromatographic procedure was then applied to the in vivo pharmacokinetic studies in rats for determining the advantages of intranasal administration of the drug over oral administration. Using liquid-liquid extraction (LLE), udenafil and the internal standard (IS) sildenafil were extracted with dichloromethane from 100 μl of plasma samples. Chromatographic separation was performed using Pursuit XRS C₁₈ column (50 mm × 2.1 mm, i.d., 3 μm, Varian Inc., CA, U.S.A.) with an isocratic mobile phase consisting of acetonitrile and 10 mM ammonium acetate (90 : 10, v/v) at a flow rate of 0.2 ml/min over a total run time of 2.5 min. Detection and quantification was performed by mass spectrometry using the multiple reaction-monitoring mode at m/z 517.4→283.1 for udenafil and m/z 475.3→100.0 for IS. Results showed that the developed method was sensitive and specific for udenafil. Linearity was obtained in the range of 0.5-1000 ng/ml. The coefficient of variation of both intra- and inter-day validation were below 11.6% and the intra- and inter-day accuracy ranged from 91.5 to 109.9%. Udenafil concentration was successfully measured from plasma after intranasal as well as after intravenous or oral administration at clinical dose (1.67 mg/kg) in rats. Moreover, the T(max) values obtained from pharmacokinetic studies suggested that administration of udenafil intranasally could be more effective than by the oral route.