Abstract
Automated DNA sequencing is an extremely valuable technique which requires very high quality DNA templates to be carried out successfully. While it has been possible to readily produce large numbers of such templates from M13 or other single-stranded vectors for several years, the sequencing of double-stranded DNA templates using the ABI 373 DNA Sequencer has had a considerably lower success rate. We describe how the combination of a new fluorescent, dideoxy sequencing method, called cycle-sequencing, coupled with modifications to template isolation procedures based on Qiagen columns, makes fluorescent sequencing of double-stranded templates a reliable procedure. From a single five milliliter culture enough DNA can be isolated (up to 20 micrograms) to do 4-8 sequencing reactions, each of which yields 400-500 bases of high quality sequence data. These procedures make the routine use of double-stranded DNA templates a viable strategy in automated DNA sequencing projects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.