Abstract

Range-gated pulsed Doppler (RGPD) ultrasonography was utilized to study the effect of a patent ductus arteriosus (PDA) on carotid arterial blood flow in small preterm infants. Carotid arterial flow velocity studies were performed on 23 preterm infants, sampling right and left carotid arteries. Studies on seven infants after PDA ligation and on seven who developed no evidence of PDA were used as controls. A strong relationship was demonstrated between diastolic reversal in the carotid arteries and PDA. The results of this study indicate that the RGPD flow velocity curve from the carotid artery is more sensitive than M-mode echocardiography or clinical examination in detecting PDA, and that PDA in small preterm infants is associated with a distinct abnormality in the carotid arterial flow pattern.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.