Abstract
This study aimed to achieve high range precision in the sub-100 µm order with time-of-flight (TOF) range imaging for 3-D scanners. The precision of a TOF range imager was improved using dual reference plane sampling (DRPS). DRPS using two short-pulse lasers reduces driver jitter, which limits the range precision below sub-100 µm. A proof-of-concept measurement system implemented using a TOF range imager demonstrated the reduction in driver jitters, resulting in reduced column-to-column variation in range precision. The developed system also achieved a high precision of 52 µm using a single frame and 27 µm using a 10-frame average.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.