Abstract
The effects of gamma radiation on common sensors used in robots intended for nuclear remediation scenarios are examined. Commercial rangefinders are chosen as an exemplar of the impact of gamma radiation on sensors and systems. This paper illustrates sensor radiation degradation not only in operational failure, but also in changes in the sensor transfer function. Three types of commercial range-finding sensors are considered [infrared (IR) triangulation using a position sensitive detector, sonar using time of flight, and laser rangefinder using triangulation and a CMOS camera]. Experimental results show significant changes in the IR sensor’s static sensitivity with dose, abrupt failure of the laser range finder at low dose, and degradation and abrupt failure for the sonar detector. The input–output relationship of the IR sensor showed further variation after a period of room-temperature annealing. Significant part-to-part variation in radiation response is shown for both the sonar and IR sensor. System level impacts due to sensor input–output relationship degradation and a technique to diagnose the degradation extendable to more complex sensor assemblies are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.