Thirteen young men, ranging in age from 18 to 26, were tested twice, 1–2 weeks apart. Venous pressure measurements were made by direct cannulation of the median antecubital vein. Measurements were taken at rest, during a 5-minute exercise on the bicycle ergometer, and during a 15-minute recovery period. The range of resting venous pressure was from 73 to 169 mm water, with a mean pressure of 120 mm water. The variability of resting pressure was very small, the standard error of measurement being 5.5 mm water. The standard error of measurement of exercise pressure was 25 mm water. The subjects showed an average increase of 118 mm water during exercise, with a range from 60 to 190 mm water. The standard error of measurement for recovery pressure was 14.5 mm water. Submitted on June 11, 1956

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.