Abstract

IntroductionDaily interruption of sedation (DIS) and sedation algorithms (SAs) have been shown to decrease mechanical ventilation (MV) duration. We conducted a randomized study comparing these strategies.MethodsMechanically ventilated adults 18 years old or older in the medical intensive care unit (ICU) were randomly assigned to DIS or SA. Exclusion criteria were severe neurocognitive dysfunction, administration of neuromuscular blockers, and tracheostomy. Study endpoints were total MV duration and 28-day ventilator-free survival.ResultsThe study was terminated prematurely after 74 patients were enrolled (DIS 36 and SA 38). The two groups had similar age, gender, racial distribution, Acute Physiology and Chronic Health Evaluation II score, and reason for MV. The Data Safety Monitoring Board convened after DIS patients were found to have higher hospital mortality; however, no causal connection between DIS and increased mortality was identified. Interim analysis demonstrated a significant difference in primary endpoint, and study termination was recommended. The DIS group had longer total duration of MV (median 6.7 versus 3.9 days; P = 0.0003), slower improvement of Sequential Organ Failure Assessment over time (0.70 versus 0.23 units per day; P = 0.025), longer ICU length of stay (15 versus 8 days; P < 0.0001), and longer hospital length of stay (23 versus 12 days; P = 0.01).ConclusionIn our cohort of patients, the use of SA was associated with reduced duration of MV and lengths of stay compared with DIS. Based on these results, DIS may not be appropriate in all mechanically ventilated patients.Trial registrationClinicalTrials.gov NCT00205517.

Highlights

  • Interruption of sedation (DIS) and sedation algorithms (SAs) have been shown to decrease mechanical ventilation (MV) duration

  • In our cohort of patients, the use of SA was associated with reduced duration of MV and lengths of stay compared with Daily interruption of sedation (DIS)

  • Baseline characteristics of 74 patients revealed no difference in age, gender distribution, racial composition, severity of illness, and reason for MV (Table 2)

Read more

Summary

Introduction

Interruption of sedation (DIS) and sedation algorithms (SAs) have been shown to decrease mechanical ventilation (MV) duration. DIS appears to be protective against the development of further organ dysfunction, while studies examining SA found neither a worsening nor an improvement of organ dysfunction [3,4,7]. Both DIS and SA have been associated with decreased administration of sedatives and opioids [1,4].

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.