Abstract
Background and ObjectivesExogenous human chorionic gonadotropin (hCG) acts on the final phase of the follicle maturation. Choriomon®, a highly purified hCG formulation, is approved in many European and extra-European countries for the induction of ovulation after stimulation of follicular development. The present study compares hCG bioavailability of Choriomon® (Test product) versus a recombinant hCG preparation (Ovitrelle®; Reference product).MethodsIn this randomized, two-way cross-over study, 26 healthy women received a single dose of Choriomon® (10,000 IU) and Ovitrelle® (250 µg; 6500 IU) by subcutaneous injection. hCG was determined in serum up to 192 h post-dose. Dose-normalized peak concentration (Cmax) and area under the concentration-time curve up to the time of the last quantifiable concentration (AUC0–t) and extrapolated to infinity (AUC0–∞) were calculated and compared between the two treatments.ResultsSerum hCG concentrations increased rapidly with a very similar pharmacokinetic curve for the two products. The test/reference geometric means ratio (GMR) for AUC0–t and AUC0–∞ corresponded to 121.31 and 119.81%, and the upper limits of the 90% confidence intervals (CIs) (130.21% and 128.51%, for AUC0–t and AUC0–∞, respectively) exceeded the 125% bioequivalence threshold. Cmax GMR was 146.89%, indicating a rate of hCG absorption approximately 50% greater for the test product (90% CI 132.30–163.10). Half-life (t1/2) was very similar (36.77 ± 5.11 h and 38.63 ± 6.08 h), whereas time to achieve Cmax (tmax) significantly differed, with median values of 16 h and 24 h for Choriomon® and Ovitrelle®, respectively, (p = 0.0023).ConclusionsThe differences between Choriomon® and Ovitrelle® pharmacokinetic parameters can be ascribed to the different raw source of the products and are reflected in the approved dose regimens of the two hCG formulations. The observed lack of bioequivalence between the two compounds at the given doses is not clinically relevant, as results from Phase III studies indicated similar clinical efficacy and safety. The safety data are in line with the known safety profile of the two products.Clinicaltrials.gov registration noNCT03735030.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.