IntroductionThe ultrasound measurement of inferior vena cava (IVC) diameter change during respiratory phase to guide fluid resuscitation in shock patients is widely performed, but the benefit on reducing the mortality of sepsis patients is questionable. The study objective was to evaluate the 30-day mortality rate of patients with sepsis-induced tissue hypoperfusion (SITH) and septic shock (SS) treated with ultrasound-guided fluid management (UGFM) using ultrasonographic change of the IVC diameter during respiration compared with those treated with the usual-care strategy.MethodsThis was a randomized controlled trial conducted in an urban, university-affiliated tertiary-care hospital. Adult patients with SITH/SS were randomized to receive treatment with UGFM using respiratory change of the IVC (UGFM strategy) or with the usual-care strategy during the first six hours after emergency department (ED) arrival. We compared the 30-day mortality rate and other clinical outcomes between the two groups.ResultsA total of 202 patients were enrolled, 101 in each group (UGFM vs usual-care strategy) for intention-to-treat analysis. There was no significant difference in 30-day overall mortality between the two groups (18.8% and 19.8% in the usual-care and UGFM strategy, respectively; p > 0.05 by log rank test). Neither was there a difference in six-hour lactate clearance, a change in the sequential organ failure assessment score, or length of hospital stay. However, the cumulative fluid amount given in 24 hours was significantly lower in the UGFM arm.ConclusionIn our ED setting, the use of respiratory change of IVC diameter determined by point-of-care ultrasound to guide initial fluid resuscitation in SITH/SS ED patients did not improve the 30-day survival probability or other clinical parameters compared to the usual-care strategy. However, the IVC ultrasound-guided resuscitation was associated with less amount of fluid used.

Highlights

  • The ultrasound measurement of inferior vena cava (IVC) diameter change during respiratory phase to guide fluid resuscitation in shock patients is widely performed, but the benefit on reducing the mortality of sepsis patients is questionable

  • In our emergency departments (ED) setting, the use of respiratory change of IVC diameter determined by point-of-care ultrasound to guide initial fluid resuscitation in sepsis-induced tissue hypoperfusion (SITH)/septic shock (SS) ED patients did not improve the 30-day survival probability or other clinical parameters compared to the usual-care strategy

  • The IVC ultrasound-guided resuscitation was associated with less amount of fluid used. [West J Emerg Med. 2021;22(2):369-378.]

Read more

Summary

Introduction

The ultrasound measurement of inferior vena cava (IVC) diameter change during respiratory phase to guide fluid resuscitation in shock patients is widely performed, but the benefit on reducing the mortality of sepsis patients is questionable. The study objective was to evaluate the 30-day mortality rate of patients with sepsis-induced tissue hypoperfusion (SITH) and septic shock (SS) treated with ultrasound-guided fluid management (UGFM) using ultrasonographic change of the IVC diameter during respiration compared with those treated with the usual-care strategy. Inferior vena cava (IVC) diameter measurement during respirophasic change is widely used to help physicians predict the fluid responsiveness in shock patients and is reasonable to tailor fluid therapy during the resuscitation.[17,18,19,20] its benefit in reducing the mortality of sepsis patients remains unclear. Secondary outcomes were the six-hour lactate clearance, amount of intravenous (IV) fluid, rate of vasopressor and mechanical ventilator (MV) use, and change in sequential organ failure (SOFA) score at 72 hours in the two groups

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.