Abstract
This research is aimed to study the contamination level of Gelaran Cajuput Oil Plant wastewater, to obtain the design of the treatment site plan, and to recommend the determination of the site plan location. The phases covered pilot field survey to determine the location, measuring the volume and collecting the sample, analizing the process and deciding the treatment system. The results showed the contamination level parameters were acid pH, and high BOD and COD. The appropriate length, width, and depth of chamber units’ dimension and specifications of the treatment yielded were respectively as follows: a) 1.5 m, 1.0 m, and 1.0 m of equalisation; b) 1.5 m, 1.0 m, and 1.0 m of neutralization; c) 1.25 m, 1.06 m, and 1.25 m of anaerobic hybrid reactor; d) 1.5 m, 1.0 m, and 1.0 m of stabilization, and was located on downward to facilitate the effluent flowing by gravitational force merely. Key Words : Cajuput oil, waste water treatment, site plan, anaerobic hybrid reactor
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.