Abstract
The rainfall in the Cilacap region is high, about 80-100mm in October-March. The high rainfall that causes the overflow of river water is unpredictable. The high water discharge is not realized until the river water overflows and causes flooding. Therefore, a river water level monitoring system is needed to detect river overflows early. This tool uses a solar cell as a power supply. The monitoring system is divided into two points of river water level monitoring system with a distance between points for the laboratory scale stage, which is 100 meters. Sensors that measure the height of river flow are ultrasonic sensors. The sensor results are processed by microcontroller and SIM 900 L module to be sent to the database . When the water level is in the Alert level 3, the buzzer will sound as a warning. The ultrasonic sensor test results have a very small error. Sensor 1 has an average error of 0.00023% and ultrasonic sensor 2 has an error of 0.00016%. The system is able to transmit river water level data that can be accessed through the website .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.