Abstract

The central solenoid of ITER is designed to operate at 13 T, 0.5-1 T/s, 5.8 K. There is an experimental evidence that reduced performances in variable field, not explained by AC loss, could occur in CIC conductors. Such ramp rate limitations have to be well understood in order to be avoided in the ITER conductors. The ENEA Nb/sub 3/Sn solenoid is a 1 m OD, 0.6 m ID coil, made of a CIC conductor which is a factor 8 smaller than the ITER full size cable. The total conductor length, 750 m, is ITER relevant. An experimental setup has been assembled, allowing ramp rate and DC tests on the ENEA coil up to 8 T, 2-4 T/s, 12 K. Main objectives of the program are experimental data on ramp rate limitation, pulsed current distribution in the s/c cable, limiting currents and global AC loss. This paper reports the results of the measurements carried out up to now.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.