Abstract
Leak detection in coolant loops of nuclear reactors is critical for the safety and performance of the reactors. The feasibility of using Raman distributed temperature sensor (RDTS) has been studied on a 30m test loop. Temperature in sodium circuits of fast Breeder Reactor (FBR) exceeds 550°C, gold coated fiber is chosen as sensor fibers. Leak is simulated through an artificial micro fissure integrated in the test loop with provision for controlled leak rate. The results are discussed in the paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.