Abstract
Fiber-optic sensors were installed on fatigue-critical components in the superstructure of a railroad bridge to monitor dynamic strains induced by trains crossing the bridge as well as to detect the onset of cracks. Each fiber Fabry-Perot interferometer (FFPI) strain gage was adhesively bonded to a stainless-steel strip to facilitate all-weather installation on the steel bridge members by spot welding. FFPI strain sensors were also installed on a rail at an approach to the bridge. Electrical resistive strain gages were colocated with the fiber-optic sensors on the bridge for the purpose of performance verification. In addition to the strain gages, fiber-optic continuity sensors for crack detection were bonded to the structure at critical locations. A telemetry system for transmitting the data over telephone lines was also installed at the bridge site. Dynamic response of the fiber-optic strain sensors is comparable with that of the electrical gages, and their performance has not degraded in the year since the initial installation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.