Abstract

Fiber-optic sensors were installed on fatigue-critical components in the superstructure of a railroad bridge to monitor dynamic strains induced by trains crossing the bridge as well as to detect the onset of cracks. Each fiber Fabry-Perot interferometer (FFPI) strain gage was adhesively bonded to a stainless-steel strip to facilitate all-weather installation on the steel bridge members by spot welding. FFPI strain sensors were also installed on a rail at an approach to the bridge. Electrical resistive strain gages were colocated with the fiber-optic sensors on the bridge for the purpose of performance verification. In addition to the strain gages, fiber-optic continuity sensors for crack detection were bonded to the structure at critical locations. A telemetry system for transmitting the data over telephone lines was also installed at the bridge site. Dynamic response of the fiber-optic strain sensors is comparable with that of the electrical gages, and their performance has not degraded in the year since the initial installation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.