The low-level gamma-ray spectroscopy as well as the investigation of rare nuclear processes require not only low, but also constant levels of relevant background radiations. In underground laboratories dedicated to this type of measurements, one of the main and hard to control sources of unwanted radiation is the radioactive gas radon. It is well-known that radon concentration varies daily and seasonally, primarily due to the variation of atmospheric parameters. This introduces unwanted and hard to evaluate systematic uncertainties in long-term low-level measurements. In this paper, the system for radon reduction in the underground Low-Background Laboratory for Nuclear Physics at the Institute of Physics in Belgrade is presented in some detail. The laboratory exists for ten years and different measurements of radon concentration were carried out during this period. The indoor radon measurements are performed using nuclear track detectors (type CR-39 and LR-115) for long-term measurements and the commercially available radon monitor for short-term measurements. In this work we present the results of these measurements for the period 2003–2008.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.