Abstract
On-site radon concentration has been measured in soil gas and ground water using AlphaGUARD PQ2000 PRO (Saphymo, Germany) radon monitor at the west coastal area of Bangladesh. The measured radon concentration in ground water samples is in the range of 1.41±0.29 to 3.2±0.59Bq/l with the mean value of 2.33±0.50Bq/l, which lies within the safe limit recommended by UNSCEAR (2008). The total annual effective dose estimated due to radon concentration in ground water ranges from 3.85 to 8.74μSv/y with the mean value of 6.37μSv/y, which is lower than the safe limit set by WHO (2004) and EU (1998). In soil samples, radon concentration has been measured at three different depths (0, 20 and 40cm) in each location. The highest and the lowest concentrations are 4790±51 and 10±04Bq/m3 at 40 and 0cm (surface) depth, respectively, which lie within the natural background levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.