Abstract

The aim of this study was to evaluate the robustness of radiomics features of a MRI (magnetic resonance imaging) phantom in quantitative diffusion-weighted imaging (DWI) and depending on the image resolution. Scanning of an in-house developed DWI phantom was performed at a 1.5 T MRI scanner (Magnetom AERA, Siemens, Erlangen, Germany) using an echo planar imaging (EPI) DWI sequence (b=0,500,1,000 s/mm2) with low (3×3 mm2) and high (2×2 mm2) image resolutions. Scans were repeated after phantom repositioning to evaluate retest reliability. Radiomics features were extracted after semi-automatic segmentation and standardised pre-processing. Intra-/interobserver reproducibility and test-retest robustness were assessed using intraclass correlation coefficients (ICC). Differences were tested with non-parametric Wilcoxon's signed-rank and Friedman's test (p<0.05) with Dunn's post-hoc analysis. Test-retest ICC was overall high with >0.90 for 39/46 radiomics features in all sequences/resolutions. Decreased test-retest ICCs were pronounced for conventional Min-value (overall ICC=0.817), and grey-level zone length matrix (GLZLM) features Short-Zone Emphasis (SZE) and Short-Zone Low Grey-level Emphasis (SZLGE) (for both overall ICC=0.927). Test-retest reproducibility was significantly different between b=500, 1,000 and apparent diffusion coefficient (ADC) (mean 0.975±0.050, 0.974±0.051 and 0.966±0.063), which remained significant after post-hoc analysis between b=1,000 and ADC (p = 0.022). ICCs were not significantly different between resolutions of 2×2 and 3×3 mm2 regarding b=500 (mean: 0.977±0.052 and 0.974±0.049, p = 0.612), b=1,000 (mean: 0.973±0.059 and 0.974±0.054, p = 0.516), and ADC (mean: 0.972±0.049 and 0.955±0.101, p = 0.851). Inter- and intra-observer reliability was consistently high for all sequences (overall mean 0.992±0.021 and 0.990±0.028). Under ex-vivo conditions, DWI provided robust radiomics features with those from ADC being slightly less robust than from raw DWI (b=500, 1,000 s/mm2). No significant difference was detected for different resolutions. Although, ex-vivo reliability of DWI radiomics features was high, no implications can be made regarding in-vivo analyses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.