Abstract

In this study, the radiological dose assessment for the most severe hypothetical accident of Tehran Research Reactor was carried out. According to the calculation results, corresponding protective actions for emergency response were obtained. The results showed that the largest distance from the reactor requires sheltering, or evacuation response is 2000m for the E and D atmospheric stability class and rainy weather condition. Also, maximum distance requiring iodine prophylaxis is 400m, for the A atmospheric stability class and calm weather condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.