Abstract

This study evaluated the accuracy of plain radiographs and computerized tomography (CT) in assessing juvenile Tillaux fractures of the distal tibia. A simulated Tillaux fracture was made in four cadaver specimens and displaced 0, 1, 2, 3, and 5 mm. Plain radiographs and CT were performed on each specimen at each amount of displacement, and the results were compared with the actual amount of displacement present. Plain radiographs and CT were accurate within 1 mm in depicting the actual fracture displacement about 50% of the time. CT was more sensitive than plain radiographs in detecting fractures with >2 mm of displacement. Fracture displacement of >2 mm is generally considered an indication for fracture reduction. Because of its sensitivity in detecting fractures displaced >2 mm, CT is the preferred imaging modality in the assessment of juvenile Tillaux fractures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.