Abstract
The purpose of this study was to evaluate the accuracy of examiners when asked to make file length adjustments with only a radiograph. The examiners viewed several radiographs under proper viewing conditions but without the aid of measuring devices. Two files of varying lengths (sizes 10 and 15) were placed in maxillary and mandibular premolars and molars from cadavers. The nine examiners were 67.91% in agreement of actual file length adjustment needed when adjustments of up to 0.5 mm were needed, 17.76% when adjustments of from 0.5 up to 1.0 mm were needed, and 14.33% when adjustments of greater than 1.0 mm were needed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.