Abstract
PurposeThe aim of the present retrospective study was to evaluate clinical and radiological outcomes, in terms of implant survival rate, marginal bone loss, and peri-implantitis incidence, of a titanium implants with an innovative laser-treated surface.Materials and methodsA total of 502 dental implants were inserted in four dental practices (Udine, Arezzo, Frascati, Roma) between 2008 and 2013. All inserted implants had laser-modified surface characterized by a series of 20-μm-diameter holes (7–10 μm deep) every 10 μm (Synthegra®, Geass srl, Italy). The minimum follow-up period was set at 1 year after the final restoration. Radiographs were taken after implant insertion (T0), at time of loading (T1), and during the follow-up period (last recall, T2). Marginal bone loss and peri-implant disease incidence were recorded.ResultsA total of 502 implants with a maximum follow-up period of 6 years were monitored. The mean differential between T0 and T2 was 0.05 ± 1.08 mm at the mesial aspect and 0.08 ± 1.11 mm at the distal with a mean follow-up period of 35.76 ± 18.05 months. After being in function for 1 to 6 years, implants reported varying behavior: 8.8% of sites did not show any radiographic changes and 38.5% of sites showed bone resorption. The bone appeared to have been growing coronally in 50.7% of the sites measured.ConclusionImplants showed a maintenance of marginal bone levels over time, and in many cases, it seems that laser-modified implant surface could promote a bone growth. The low peri-implant disease incidence recorded could be attributed to the laser titanium surface features that seem to prevent bacterial colonization. Future randomized and controlled studies are needed to confirm the results of the present multi-centrical retrospective analysis.
Highlights
Dental implant-supported rehabilitations are safe and predictable therapies [1,2,3,4,5] whose rising demand varies according to the patient population ages [6]
Implants showed a maintenance of marginal bone levels over time, and in many cases, it seems that laser-modified implant surface could promote a bone growth
The low peri-implant disease incidence recorded could be attributed to the laser titanium surface features that seem to prevent bacterial colonization
Summary
Dental implant-supported rehabilitations are safe and predictable therapies [1,2,3,4,5] whose rising demand varies according to the patient population ages [6]. In non-pathological conditions, after implant insertion and prosthetic loading, Mongardini et al International Journal of Implant Dentistry (2020) 6:29 marginal bone loss appears more pronounced during the first year in function continuing slowly thereafter. The amount of initial crestal remodeling has been observed to be related to host factors, implant design, surgical protocol, and restorative protocols [13]. Surface features [10], neck design [15], or the micro-gap between fixture and abutment seemed to be all involved in peri-implant bone remodeling phenomena. A recent review demonstrated that crestal bone levels are better maintained in the short-medium term when internal fixture-abutment connections are adopted, and among them, conical connections seem to be more advantageous, showing lower periimplant bone loss [16]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.