Abstract

Piroxicam was labeled effectively with 99mTc due to the presence of electron donating atoms such as sulfur, nitrogen, and oxygen in its structure. The labeling yield was found to be influenced by different factors such as the amount of piroxicam, stannous chloride dihydrate, pH of the reaction mixture, reaction time and reaction temperature. The suitable amount of stannous chloride dihydrate required to produce high labeling yield of 99mTc-piroxicam was 50 μg, above this quantity (200 μg) a colloidal solution was formed. Another factor which plays a significant role in this labeling reaction is the pH of the reaction medium. The labeling reaction was done only at alkaline pH range from 9-11, because piroxicam was not soluble at acidic or neutral pH. The labeling reaction proceeded well at room temperature and the complex was decomposed by heat. The labeled piroxicam (99mTc-piroxicam ) showed good localization in inflamed foci and good imaging must be taken at 24-hour post injection, as the ratio of both types of inflammation (sterile and septic) to the background are 10.6 and 8.7, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.