Abstract

Purpose : To determine the relative biological effectiveness (RBE) for initial and delayed inactivation of cells by a modulated proton beam suitable for the treatment of tumours of the eye, within the spread-out Bragg peak and in its distal declining edge. Materials and methods : Human tumour SCC25 cells were irradiated with the 65 MeV proton beam at the Cyclotron Medicyc in Nice. Perspex plates of different thickness were used to simulate five positions along the beam line: 2 mm corresponding to the entrance beam; 15.6 and 25mm in the spread-out Bragg peak; 27.2 and 27.8mm for the distal edge. At each position clonogenic survival of the irradiated cells and of their progeny were determined at various dose values. 60 Co γ-rays were used as reference radiation. Results : RBE values evaluated at the survival level given by 2 Gy of γ-rays increased with increasing depth from close to 1.0 at the proximal to about 1.2 at the distal part of the peak. Within the declining edge it reached the value of about 1.4 at 27.2 and about 2 at 27.8 mm. For the progeny of irradiated cells, the RBE value ranged from 1.0 to 1.1 within the spread-out Bragg peak and then increased up to a value of 2.0 at the last position. The dose-effect curves for the progeny always had a larger shoulder than for the irradiated progenitors, their α parameters being lower by a factor of about 4 and their β parameters always being higher. The alpha/beta ratio was about 50Gy for the progenitors and about 6Gy for their progeny. The incidence of delayed eÚects increased with dose and with the depth within the beam. Conclusions : RBE values for the inactivation of cells irradiated in the spread-out Bragg peak are compatible with the value currently assumed in clinical applications. In the distal declining edge of the beam, the RBE values increased significantly to an extent that may be of concern when the region of the treatment volume is close to sensitive tissues. The yield of delayed reproductive cell death was significant at each position along the beam line.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.