Abstract

A four-rod radio frequency quadruple (RFQ) accelerator is designed, manufactured, installed and commissioned for the Peking University Neutron Imaging Facility (PKUNIFTY). This 2699.6-mm-long RFQ accelerator with the mean aperture radius of 3.88mm is operating at 201.5 MHz in pulse mode. An inter-electrode voltage of 70 kV is needed to accelerate the injected 50 keV 40 mA D+ ions up to 2 MeV. We present the rf system, high rf power feeder design, lower rf measurements and higher rf power test. Especially, the rf commissioning was carried out with rf power up to ∼280 kW and duty factor of 4%. The measured x-ray spectrum shows that the rf inter-electrode voltage reaches 70.7 kV. It is found that the specific shunt impedance of the RFQ cavity reaches 52.7 kΩ·m.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.