Abstract

Influence of magnetic field configuration on ring-shaped hollow cathode discharge has been investigated in order to perform high-density plasma sources under a low gas pressure of a few tens mTorr. Three typed arrangements of permanent magnets such as (a) NS-NS, (b) NS-SN and (c) NS are examined. The NS-NS arrangement has a divergent profile with a peak in axial direction in hollow cathode. The NS-SN placement forms a cusp profile with a mirror configuration in axial direction. In final, the NS setup assigns a conventional divergent field. For the cases of (a) NS-NS and (b) NS-SN arrangements, their plasma density keeps a higher order of magnitude of 1011 cm−3 at the wide range of gas pressure of 10–200 mTorr. On the other hand, the NS arrangement maintains only the order of magnitude of 1011 cm−3 at the region of gas pressure more than 30 mTorr. All radial profiles of plasma density near the hollow cathode show non-uniformity like M-shaped distribution. However, it is found that the uniformity of their radial profiles depends on the arrangement of permanent magnets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.