Abstract
Abstract The degradative effects of γ-radiation on diethyl ether solutions of poly(alkyl vinyl ethers) under a variety of conditions were studied by polymer molecular weight measurements. Poly(methyl vinyl ether) (PMVE), poly(ethyl vinyl ether) (PEVE), poly(isopropyl vinyl ether) (PIPVE), and poly(isobutyl vinyl ether) (PIBVE) exhibited similar degradative behavior, with G(SC) values between 0.3 and 0.9 scissions/100 eV at 0°C. Chemically polymerized and radiation-polymerized PEVE samples gave comparable results. Chain degradation was much more pronounced for samples of poly(tert-butyl vinyl ether) (PTBVE) which yielded a G(SC) value of 3.6 at 0°C. Degradation experiments conducted on PEVE in air resulted in significantly higher rates of scission: G(SC) = 5.6 scissions/100 eV at 0°C. Chain scission was not measurably influenced by changing the solvent from diethyl ether to di-isopropyl ether. Increased polymer concentration was found to reduce the rate of polymer degradation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Macromolecular Science: Part A - Chemistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.