Abstract

This paper concentrates on the selection of radiation tolerant isolation amplifiers, which are suitable for the signal conditioners for cryogenic system in the Large Hadron Collider (LHC). The evolution and the results of different commercial isolation amplifiers’ parameters under neutron and gamma radiation are presented. In most cases, the tested isolation amplifiers’ input offset voltage, bias currents and output offset voltage hardly changed during the radiation. The DC gain in input stage was only affected for some isolation amplifiers with a small open loop gain. Transmission coefficient showed decrease for all the tested isolation amplifiers. Also, the DC output voltage increased and the ripple voltage decreased for all the build-in isolated regulators. In addition, results on 1B41 signal conditioner showed that it was tolerant to 7–8×10 12 n/cm 2, which was 50% higher than the expected dose in the LHC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.