Abstract

ObjectivesWe aimed to evaluate the outcomes of the Radiation Therapy Oncology Group 8502 “QUAD shot” regimen using volumetric modulated arc therapy (VMAT) for incurable head and neck cancer (HNC). Materials and methodsWe included 105 patients with HNC in the study, undergoing at least one QUAD shot regimen cycle. We planned the radiotherapy using VMAT with 6 MV photons. One QUAD shot cycle included 14.8 Gy in 4 fractions with at least 6-hour intervals over 2 consecutive days, repeated every 3–6 weeks up to 3 cycles. ResultsWe completed 1, 2, and 3 cycles in 11 (10 %), 17 (16 %), and 77 (73 %) patients, respectively. We concurrently performed systemic therapy in 13 (12 %) patients. Tumor response was observed in 92 (88 %) patients and at least one symptom relief in 51 (71 %) of 72 patients. We observed an overall response (tumor response or symptom relief) in 98 (93 %) patients with all patients who completed 3 cycles achieving it. The median overall survival (OS) was 6.8 months. Our multivariate analysis revealed that non-squamous cell carcinoma (p < 0.001), T category of 0–2 (p = 0.021), and 3 QUAD shot cycles (p < 0.001) were independent prognostic factors of better OS. We observed Grade 3 toxicity in 2 (2 %) patients while no ≥ Grade 4 acute or ≥ Grade 3 late toxicity. ConclusionsThe QUAD shot regimen using VMAT exerts appropriate palliative effect in patients with incurable HNC. Treatment with higher QUAD shot cycle number would be recommended for better treatment outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call