Abstract

Many void gaps originated from assembly/disassembly concept of reactor structures exist in a tokamak reactor. Radiation streaming through these gaps causes hot spots in terms of irradiation of in-vessel components and of biological dose rate in personnel access area. For two-dimensional analysis of streaming through such a narrow gap, the discrete ordinates (S N) method suffers from ray effects. In this paper, therefore, necessary conditions for angular quadrature were fist investigated by comparing the S N results with the line-of-sight results and the Monte Carlo results. As a result, it was found that the biased 166 angular quadrature (131 forward angles) gave results with practically sufficient accuracy for shielding design with some correction for the ray-effect. Also, local peaking factors due to the gap streaming were obtained as a function of gap width and shield thickness, and they are useful for future shielding design. Based on these preliminary investigations, the design calculation for the FE...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.