Abstract
Several noble gas mixtures containing CF4 were irradiated at high neutron and gamma dose rates to determine their radiation stability for neutron flux monitoring applications where the total radiation dose can be large. Five test detectors (ionization and proportional counters employing either 3He or 235U as the sensitizing material) containing CF4 gas mixtures were irradiated in a neutron flux of ~1011 n·cm-2·s-1 and a gamma field of ~2 × 108 R/h. All detectors exhibited moderate to total degradation of pulse response at fluences from 1015 to 1016 n·cm-2, with more rapid degradation occurring in the fission detectors. The pulse height degradation was probably caused by electron attachment on irradiation products such as C2F6, C3F8, and CF3OF, which were detected at 100-to 6000-ppm levels in subsequent mass spectrometric analyses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.