Abstract
Radiation spectra for radionuclides currently provided by the MIRD Committee and ICRP do not include the very low-energy N- and O-shell Auger electrons. These electrons, emitted in large numbers by radionuclides decaying by electron capture and/or internal conversion, are important for determining the absorbed dose in microscopic volumes. Accordingly, the present AAPM Report employs Monte Carlo computational methods to obtain a self-consistent set of complete radiation spectra for a variety of radionuclides including 55Fe, 67Ga, 99mTc, 111In, 113mIn, 115mIn, 123I, 125I, 193mPt, 195mPt, 201Tl, and 203Pb. Although the conventional spectra provided by MIRD and ICRP are adequate for most dosimetry calculations, the Auger electron spectra provided in this report are recommended for calculating the dose to target volumes < 1 microns in diameter.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.