A radiation shielding study against primary and secondary gas bremsstrahlung is carried out for the existing transverse wall at the Canadian Light Source (CLS). A Monte Carlo method for mapping the radiation dose behind the transverse wall is developed. Two shielding methods are studied: (1) local shielding and (2) a lead wall, to bring the radiation level below the regulation limit. Also discussed are the lead beam stops used for an insertion device (ID) and a bending magnet (BM) beamline since there exists a considerable difference in length of the straight section between the ID and BM beamlines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.