In this work, were determined some radiation shielding and dosimetric parameters of three types of bricks for photons energy from 1 keV to 100 GeV photons using the Phy-X/PSD software, and for comparison also has been calculated the same parameters for NBS concrete. The parameters calculated are the linear attenuation coefficients (LAC), effective atomic numbers (Zeff), half value layers (HVL), the energy absorption buildup factors (EABF) and the exposure buildup factors (EBF), as well as the coefficients to use the geometric progression (G-P) fitting method. Obtained results show that the three types of bricks can be used safely for the design of medical facilities housing mammography units (less than 30 keV).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.